There are seven buttons on the operation panel of the pass box (power button, door open button, setting button, sterilization button, fan button, up button, down button). Set the time for sterilization, fan, and lighting before use (0-999 seconds or 0-999 minutes). The original settings were sterilization for 20 seconds, air supply for 30 seconds, and lighting for 0 seconds.
Time setting: (If you need to set sterilization for 40 seconds, air supply for 50 seconds, and lighting for 10 seconds) Press and hold the setting button for 3 seconds, then release it. The setting button indicator light will light up, and the sterilization indicator light will flash. Press the up and down adjustment keys to adjust the time to 40; Press the setting button again (at this time, there is no need to hold it down for 3 seconds), the air supply indicator light will flash, and press the up and down adjustment keys to adjust the time to 50; Press the setting button again (without holding it down for 3 seconds at this time), the power indicator light will flash (this is the lighting time setting), and press the up and down adjustment keys to adjust the time to 10. Note: When setting the time, all three sets of time must be set with the setting indicator light on, otherwise it will be invalid.
Suzhou Pharma Machinery Co.,Ltd.
2023/05/12
Birkey
Copyright © 2024 SUZHOU CO.,LTD. | All Rights Reserved.