The Key Points of Choosing Clean Room


 

Clean room needs to remove pollutants such as particles, harmful air and bacteria in the air within a certain range. In order to achieve these effects, a specially designed clean room regardless of how the external air changes, can maintain the original requirements of cleanliness, temperature, humidity, pressure and other performance.

 

The composition of the clean room:

1. Ceiling system consists of ceiling rod, I-Beam or U-Beam, ceiling frame;

2. Air conditioning system consists of filter system, air blower, etc;

3. Building envelope consists of wall panel, floor, door, connection fittings;

4. Clean room equipment such as pass box, air shower, biological safety cabinet,LED lamp, sterilization lamp, etc.

 

According to the construction features, we summarize the key points to choose an eligible clean room:

1. Building envelope standard

The surface of the clean room should be smooth, tight interface, no cracks. The materials selected for clean room construction should be resistant to cleaning and disinfection. The boundary between walls, walls and ceilings, walls and floor should be curved, to reduce the accumulation of pollutants.

2. Illumination standard

The shape of the lamp can not accumulate dust, so the design must be in accordance with the requirements of fluid mechanics, without any convex, concave, gap and segment difference. The surface should be smooth and uniform, can not absorb dust, can be met by anti-static treatment. The lamp should not obstruct airflow, so it is designed to be recessed, that is, installed into the ceiling of the clean room. When the lamp is embedded in the ceiling, the gap should be installed with reliable sealing measures.

3. Temperature and humidity standard

The temperature and humidity of the clean area should be appropriate to the requirements of the application site. When there is no special requirement, the temperature should be controlled between 18 ℃ and 26℃, and the relative humidity should be controlled between 45% and 65%.

4. Air clean standard

The air supplied to clean areas must be purified. The air entering the clean area is generally filtered by the air conditioning system through the three-stage filter (coarse effect, medium effect and high efficiency) to make the air reach the required clean level. The clean room should have a certain air supply volume of air conditioning. The necessary pressure gradient (positive or negative pressure gradient) should be maintained in the clean room. And the clean room should have reasonable air distribution.

 

 

news-The Key Points of Choosing Clean Room-PHARMA-img                 
news-PHARMA-img                 

Suzhou Pharma Machinery Co.,Ltd.

2023/04/27

Spencer


prev
What Is The Difference Between a Class 1 And Class 100 Cleanroom?
How Use Class 100 Laminar Flow Hood Cleanroom Clean Bench
next
recommended for you
no data
GET IN TOUCH WITH Us
Contact Us
Telephone: +86-18241958031/
+86-18913598640
Fax: 86-512-65488640
Whatsapp/Wechat: 008618241958031

Notice:
We hereby declare that our company's only legal contact is through the  Email pharma@sz-pharma.com, Any other similar suffix is a scammer email. 


Address: NO.188 xiangwei road, near junction of xiangwei road and chengyang road (the second floor of south building inside of haiji feiyue) Xiangcheng district, Suzhou city, Jiangsu province, China
no data
Copyright © 2024 Suzhou Pharma Machinery Co., Ltd. | Sitemap
Customer service
detect