Sterile clean laboratory facilities and environmental requirements?

The environmental control of clean laboratory mainly includes isolation, lighting, energy, temperature and humidity, cleanliness, noise control, air supply and water supply, ventilation and exhaust, radiation protection, etc. in different areas, and has special technologies for related facilities and environmental conditions If required, it must be documented and...

Text Label: Sterile Clean , Facilities and Environmental Requirements

Sterile clean laboratory facilities and environmental requirements?

The environmental control of clean pharma machinery mainly includes isolation, lighting, energy, temperature and humidity, cleanliness, noise control, air supply and water supply, ventilation and exhaust, radiation protection, etc. in different areas, and has special technologies for related facilities and environmental conditions If required, it must be documented and posted on the wall in the relevant area to facilitate the access and monitoring of relevant personnel. Clean laboratory water and electricity facilities: water and electricity are facilities that are frequently used on a daily basis. All kinds of experimental instruments and equipment need to be powered on before they can be used, especially for some high-power instruments and instruments and equipment that have strict requirements on voltage, and the voltage should be stable. , Electric power and ground voltage meet the requirements, install leakage protection devices to ensure safe use of electricity; the laboratory should try to plan a gas cylinder room where gas cylinders are placed uniformly, and the gas cylinder room must be kept cool, dry and away from heat sources. Place it upright and fix it upright, place it when it is dumped, collided, roll, handle it with care, and check the gas cylinder regularly. Unqualified gas cylinders should not be used. The direction of the pressure valve and the gas path should be standardized, and the leakage of air will affect the safety. Especially when using hydrogen, ethylene, acetylene and other gases, attention should be paid to the standardized use. After the experiment is completed, the water, gas and power must be turned off.

Ventilation requirements for clean laboratories: Good ventilation conditions should be maintained. Volatile organic solvents and tests that produce harmful gases should be carried out in a fume hood. A reasonable number of fume hoods, universal Facilities such as hoods and extraction cabinets ensure that a large amount of harmful gases are not retained in the laboratory, and there is no strong odor of volatile organic reagents. Cleanliness and temperature and humidity control facilities: should be equipped with dustproof and temperature and humidity control equipment according to requirements, especially when the dust in the surrounding environment of the laboratory is serious, some precision analysis and testing instruments have stricter requirements on dust and temperature and humidity, clean laboratory Whether it has good cleanliness and relatively constant temperature and humidity has a great impact on ensuring the accuracy and stability of the detection and calibration results. Well-controlled cleanliness and temperature and humidity are also conducive to the maintenance and service life of instruments and equipment. Regional isolation requirements: The business work carried out should be reasonably arranged, and effective isolation measures should be taken when any activities between two adjacent areas have an adverse impact on each other, so as to prevent affecting the quality of testing, calibration work and the environment. To avoid cross contamination, each isolated area should be clearly marked; the organic testing area and the inorganic testing area of u200bu200bthe sterile laboratory should be separated, and the storage area of u200bu200borganic reagents should be separated from the high-temperature heating area by a certain distance. Trace detection and commodity quality analysis The area should be isolated, and some equipment working areas and office areas with mechanical pumps, compressors and other noisy equipment should also be distributed in different areas. Zhongjing Global Purification can provide consulting, planning, design, construction, installation, transformation and other supporting services for clean laboratories and sterile laboratories.

The laboratory should be equipped with fire safety facilities that meet the requirements of relevant regulations, and the type, quantity and location of various fire protection facilities should be specified, and regular inspections should be made to ensure that the fire protection settings are within the validity period. At the same time, all relevant personnel should be familiar with the use of fire protection facilities. method. The clean pharma machinery should have relatively complete collection and treatment facilities for waste water, waste gas and solid waste. The waste gas must be purified and treated by the exhaust system before it can be discharged into the atmosphere. Various organic and inorganic waste liquids should also be collected separately and unified. Disposal; correctly equip various waste collection and disposal facilities and equipment to ensure that the waste gas, waste liquid, solid waste, as well as dust, noise, etc. generated during the detection and calibration process can be properly treated, and the treatment effect meets the requirements of environmental protection. Affect the environment and health, and make corresponding records.

SUZHOU PHARMA MACHINERY CO.,LTD. devises a regular, independent, transparent and objective assessment mechanism to evaluate country performance.

SUZHOU PHARMA MACHINERY CO.,LTD. would like to provide our customers with as near perfect protection, as near perfect service as is humanly possible and to do so at the lowest possible cost.'

Along the way, SUZHOU PHARMA MACHINERY CO.,LTD. will face a wide range of challenges. The most successful will show our resolve by working through the challenges and finding ways to improve and grow.

GET IN TOUCH WITH Us
recommended articles
Project
Clean Room Pressure Difference Influencing Factors And control Methods
A professional clean room must control the pressure difference to ensure that air flows from clean areas to non clean areas and from high cleanliness areas to low cleanliness areas during normal use, thereby maintaining clean air in the clean room at all times.
In depth Analysis of Sterile Isolators
Aseptic isolators are enclosed spaces composed of rigid and/or flexible barrier materials. They contain an integrated vaporized hydrogen peroxide (VHP) sterilization system, which can repeatedly sterilize the air inside the isolator and effectively exposed surfaces to remove the bioburden.
Clean Room PVC Floor
Cleanroom pvc flooring is a polyvinyl chloride (PVC) material specifically designed for clean room environments. It has a high density and smooth surface.
Thoughts on the Applicability of Laminar Flow Interference Testing in Clean Areas

In clean area management and quality control, laminar flow interference testing has received much attention, and whether it is only applicable to Class A laminar flow remains to be considered.
no data
Contact Us
Telephone: +86-18241958031/
+86-18913598640
Fax: 86-512-65488640
Whatsapp/Wechat: 008618241958031

Notice:
We hereby declare that our company's only legal contact is through the the above email, Any other similar suffix is a scammer email. 
Address: NO.188 xiangwei road, near junction of xiangwei road and chengyang road (the second floor of south building inside of haiji feiyue) Xiangcheng district, Suzhou city, Jiangsu province, China
no data
Copyright © 2025 Suzhou Pharma Machinery Co., Ltd. | Privacy Policy  Sitemap
Contact us
email
whatsapp
contact customer service
Contact us
email
whatsapp
cancel
Customer service
detect