Focuses On Professional Cleanroom Project And Pharmaceutical Cleanroom Equipment.

Process flow chart of pure water treatment system - water purification

Figure 1 The commonly used primary RO+ secondary EDI+MB electronic I-level ultrapure water system process configuration diagram is suitable for source water with high hardness, high organic content, high electrical conductivity (less than 1000μs/cm), and the required water resistivity 18~ 18.2MΩ·cm ultrapure water system Figure 2 The commonly used primary RO + secondary EDI electronic Ⅱ level ultrapure water system process configuration diagram is suitable for the source water with high hardness, high organic content, electrical conductivity (less than 1000μs/cm), requirements Ultrapure water system with produced water resistivity of 15-18MΩ·cmFig. 5 Commonly used primary RO + secondary EDI electronics + MB electronics I-level ultrapure water system process configuration diagram It is suitable for source water with low hardness, low organic content, and electrical conductivity High (less than 1000μs/cm) ultrapure water system with a water resistivity of 18-18.2MΩ·cmFig. 6 Process configuration diagram of a commonly used first-level RO + second-level EDI electronic II-level ultrapure water system is suitable for low source water hardness , low organic content, high electrical conductivity (less than 1000μs/cm), and ultrapure water system that requires a water resistivity of 15-18MΩ·cm Figure 7. The composition diagram of the commonly used secondary RO+ primary EDI+MB electronic primary ultrapure water system with stable water quality is suitable for the source water with low hardness, high organic content and electrical conductivity.

GET IN TOUCH WITH Us
recommended articles
Project
Clean Room Pressure Difference Influencing Factors And control Methods
A professional clean room must control the pressure difference to ensure that air flows from clean areas to non clean areas and from high cleanliness areas to low cleanliness areas during normal use, thereby maintaining clean air in the clean room at all times.
In depth Analysis of Sterile Isolators
Aseptic isolators are enclosed spaces composed of rigid and/or flexible barrier materials. They contain an integrated vaporized hydrogen peroxide (VHP) sterilization system, which can repeatedly sterilize the air inside the isolator and effectively exposed surfaces to remove the bioburden.
Clean Room PVC Floor
Cleanroom pvc flooring is a polyvinyl chloride (PVC) material specifically designed for clean room environments. It has a high density and smooth surface.
Thoughts on the Applicability of Laminar Flow Interference Testing in Clean Areas

In clean area management and quality control, laminar flow interference testing has received much attention, and whether it is only applicable to Class A laminar flow remains to be considered.
no data
Contact Us
Telephone: +86-18241958031/
+86-18913598640
Fax: 86-512-65488640
Whatsapp/Wechat: 008618241958031

Notice:
We hereby declare that our company's only legal contact is through the the above email, Any other similar suffix is a scammer email. 
Address: NO.188 xiangwei road, near junction of xiangwei road and chengyang road (the second floor of south building inside of haiji feiyue) Xiangcheng district, Suzhou city, Jiangsu province, China
no data
Copyright © 2025 Suzhou Pharma Machinery Co., Ltd. | Privacy Policy  Sitemap
Contact us
email
whatsapp
contact customer service
Contact us
email
whatsapp
cancel
Customer service
detect