Precautions for Using the Class 100 Cleanroom

Precautions for Using the Class 100 Cleanroom

2024-08-01




news-PHARMA-img

Class 100 clean room refers to the number of particles per cubic foot of air with a diameter greater than or equal to 0.5 microns does not exceed 100, usually corresponding to ISO Class 5 clean room. It is mainly used in medical, pharmaceutical industry, semiconductor industry, nano-research, biotechnology and other fields.This type of clean room has a very high degree of cleanliness, so it is necessary to strictly adhere to a series of precautions to ensure the cleanliness of the environment and the safety of operation. Use clean rooms properly. Strictly control the entry and exit of personnel and materials to reduce the number of entry and exit as much as possible. The items in the clean room are placed reasonably and easy to operate.





Strict dress code. Personnel entering the clean room should change sterile clothing, wear shoes and hats, and go through the shower. All items entering the clean room should be disinfected or cleaned to prevent the introduction of contaminants.
Strengthen personnel training, actively carry out theoretical learning, clarify the working principle and environmental requirements of laminar flow 100-level purification room, and be familiar with the basic knowledge and operational requirements of training. Strictly regulate the behavior of personnel and various operating rules and regulations. Regularly check and maintain the equipment in the class 100 cleanroom to ensure its normal operation.
news-PHARMA-Precautions for Using the Class 100 Cleanroom-img

 

Set up strict work procedures and clearly distinguish decontamination areas. Develop a rigorous workflow. Regular special personnel to check the operation of the air conditioning system, do a good job of maintenance. Remove dust from doors, Windows and floors before and after daily operation. It should be cleaned once a week, including the ceiling, walls and floor, especially the ventilation and return air outlet are easy to store dust and bacteria; To disassemble and clean regular inspection and replacement. The primary and middle effect filters are replaced once every 6 months, and the high efficiency filters are replaced once every 1 to 2 years.

news-Precautions for Using the Class 100 Cleanroom-PHARMA-img
news-PHARMA-img-1
news-PHARMA-Precautions for Using the Class 100 Cleanroom-img-1


Based on rich experience in purification engineering, Suzhou Pharma provides personalized and customized service solutions to meet the specific needs of different customers. To provide customers with reliable and high quality service is our philosophy. We welcome your inquiries from all over the world~



Suzhou Pharma Machinery Co.,Ltd.

2024/08/01

Tia




Chat Online
Chat Online
Leave Your Message inputting...
Sign in with: