Focus On Professional Factory Cleanroom Workshop Project And Machinery Only Phone:+8618241958031 Email: pharma@sz-pharma.com
Notice: We hereby declare that our company's only legal contact is through the WhatsApp/phone number: +86 18241958031 / Email:pharma@sz-pharma.com, Any other similar suffix is a scammer email.
After Warranty Service: Video technical support, Online support
Wind speed m/s: 0.45m/s +_ 20%
Name: Cleanroom weighing booth
After-sales Service Provided: Field installation, commissioning and training
Material: SUS304
Noise dB(A): <72DB(A)
Marketing Type: New Product 2020
Certification: CE
Limit Discounts
Description
Reverse weighing booth is ideal for operator protection and environment protection. Dust particles are being filtered and clean air stream is provided in the zone of exposed product and the operator breathing zone. The design to provide class 100 working environment at rest with bulit in scavenging system to ensure product, operator & surrounding environment cleanliness. Through effect filter and HEPA filter, air is pushed by weighing booth from the centrifugal fan to plenum chamber, then flows out through HEPA filter, forming a vertical unidirectional flow to protect operators and prevent contamination of drugs. Weighing booth’s operating area discharges 10% of the circulating air to maintain the negative pressure to prevent pollution of the environment and pharmaceutical cross-contamination.
The weighing booth is made of SUS304 stainless steel plate. There are configuration tank HEPA air filter on the top; and at the bottom of the weighing chamber, configure the primary and middle efficiency air filter are equipped. Weigh the top of the chamber and configure a uniform flow membrane to make the wind blow evenly.
Internal configuration of weighing booth is high power low noise centrifugal fan. The weighing booth is equipped with two differential pressure gauges and a lifting table. The overall structure of the weighing chamber is split type, which can be assembled on site.
Technical Parameters
Model | PH-W series |
Class/Air Flow | ISO5 0.45±20%m/s |
CRI | >Ra 80 |
Pre-filter | G4 (90%@5um) |
Med-filter | F8 (85%~95%@1~5um) |
Power Supply | 380V/3Ø/50Hz(Advice if different) |
Control Mode | VFD Control/Simens PLC Control |
UV Light | Optional |
Light Intensity | ≥300Lx |
Nose | ≤70dB (A) |
Different Pressure Gauge(3 nos.) | 0-60Pa/0-250Pa/0-500Pa |
MOC | SUS304/1.2mm |
Installation