Medical lab space requirements?
The indoor clear height of the locker room and laboratory should not be lower than 2.6m when air conditioning is not provided, and should not be less than 2.4m when air conditioning is provided. The indoor clear height of the laboratory should also be Determined according to the requirements of laboratory equipment size, installation and maintenance...
Text Labels: Setup Requirements, Medical Space Requirements
Medical lab space requirements?
The indoor clear height of the locker room and laboratory should not be lower than 2.6m when air conditioning is not provided, and should not be less than 2.4m when air conditioning is provided. The indoor clear height of the laboratory should also be It is determined according to the requirements of laboratory equipment size, installation and maintenance; the standard unit bay should be determined by the laboratory width, layout and spacing; on the premise of meeting the lighting requirements, the windows should also ensure the permeability of the laboratory; The width of the main door of the room passage is 1.5m, the width of the laboratory door where large instruments and equipment are to be placed is generally 1.2m, the width of the doors of other departments is generally 0.9m, and the doors should be equipped with observation windows; the width of the passage between the workbenches is generally 1.5m -1.8m, the width of the workbench from the wall is generally 1.2-1.5m, the width of the passage between the workbench and the instrument should not be less than 1.8m; the width of the passage between the two instruments is recommended to be 2-2.5m, the instrument The recommended width between the equipment and the workbench should be set to not less than 1.8m, and the recommended width between the equipment and the wall should be set to 1.8m; There should also be a space of not less than 30cm at the top. The recommended minimum space for the side-to-door distance of the biological safety cabinet is 1m, the minimum distance for diagonally opposite doors is 1.8m, and the minimum distance for people to operate with their backs to the door is 1.5m.
If the public aisle in the clean area is a single-sided cloth room, the minimum net width should not be less than 1.3m, the minimum clear width of a single-aisle double-sided cloth room should not be less than 1.6m, and if the public aisle in the polluted area is a single-sided cloth room, the minimum net width It should not be less than 1.5m, and the minimum net width of the double-sided cloth room should not be less than 1.8m; the clean area is an area for laboratory personnel to do office activities, study and rest, and should be set up as an independent area, separate from semi-polluted areas and polluted areas. The cleaning area should be reasonably planned according to the overall layout of the laboratory, which is convenient for work and does not interfere with each other; the duty room should be set as close to the waiting area as possible. Switches, the setting of the duty room should be separated for men and women, and the duty room should be equipped with toilets if conditions permit; there should be required sleeping appliances and clothing storage cabinets; there is no specific grade requirement for decoration, and the wall materials are allowed to be painted with wall tiles Finished with latex paint. Zhongjing Global Purification can provide consulting, planning, design, construction, installation, transformation and other supporting services for laboratories and clean rooms.
The locker room should be set up as an independent area, separate from other laboratories, with an access control system at the door, non-staff members are not allowed to enter, it is a necessary area for the staff to enter the laboratory from the public area, and the staff must pass from the locker room Entering the laboratory after changing clothes is a semi-contaminated area. Lockers and wash basins must be set up according to the number of laboratory personnel; physical partitions must be provided between the locker room and the cleaning area and the laboratory area. The decontamination room is used for washing utensils and sterilizing pharma machinery infection waste. It should be equipped with washing table, utensil rack, eye washer, drying box, autoclave, etc. The water tank of the washing table can be selected from multiple large sinks, which is convenient for washing. The drip rack on the washing table is convenient for drying the utensils; the location of the cleaning room must be planned close to the sewage ladder, which is convenient for the transportation of the waste after the disinfection treatment in the cleaning room, and it is inconvenient to open the door in the direction of the sewage ladder. A large transfer window can be used for transportation.
SUZHOU PHARMA MACHINERY CO.,LTD. has created a professional team which contained with a numbers of engineers and technology experts.
As a global CUSTOM SOLUTION SERVICES company, we take on some of the world’s biggest CUSTOM SOLUTION SERVICES challenges. SUZHOU PHARMA MACHINERY CO.,LTD. have a whole series of extraction machine CUSTOM SOLUTION SERVICES that can solve your CUSTOM SOLUTION SERVICES problem in an effective manner. Check it at PHARMA MACHINERY.
Offering a loyalty program not only makes customers feel valued, but it allows SUZHOU PHARMA MACHINERY CO.,LTD. to easily collect important information about customers.
Many homeowners find that they can cut costs while keeping home cool efficiently with .