loading

Focuses On Professional Cleanroom Project And Pharmaceutical Cleanroom Equipment.

Installation and preparation of turbo single-punch tablet press

Do not dismantle the protective cover and safety cover device on the rotary pharma machinery, but install it properly when using it. The punching die needs to go through strict flaw detection test and appearance inspection. It must be free of cracks, deformation, missing edges, suitable for hardness and accurate in size. If it is unqualified, do not use it to avoid serious damage to the rotary . The feeder device is level with the turntable surface, and the height is accurate. If it is too high, powder leakage will occur, and if it is too low, copper scraps will fall off and affect tablet quality. Do not use raw materials with a lot of fine powder, because it will cause more flying powder in the upper punch and more leakage in the lower punch, which will affect the easy wear of the machine parts and the loss of raw materials. Do not use raw materials that are not dry, as it will cause the powder to stick to the punch face. If there is a jumping piece or stagnation during operation, it must not be picked up by hand, so as not to cause hand injury accidents. When driving, start the motor first, and then start the clutch after it is running normally. If you find abnormal vibration or abnormal noise during use, stop the machine immediately for inspection. The pressure should not be too high during use. Generally, it is measured by the load of the motor. It is normal for the heavy-load current of a 380-volt motor to not exceed 4 amperes when pressing tablets. Increase of difference in tablet weight: During the process of adding tablets, the difference in weight cannot exceed the limit stipulated in the Pharmacopoeia to be qualified. The adjustment method of the tablet weight of the rotary : During the pressing process, it is often found that the difference in tablet weight increases. Use the punch after passing the inspection. If there is an individual decrease, it may be due to the failure of the lower punch movement, resulting in less filling of the particles. It is necessary to check out the individual lower punch and remove the obstacle. The height device of the hopper is not correct: it can cause the particles in one hopper to fall fast, while the particles accumulated on the feeder are more, the speed of the particles in the other hopper is slower, and the particles accumulated on the feeder are less , resulting in imbalance when the particles are added to the die hole, the position of the feeding hopper can be adjusted so that the number and falling speed of the particles in the two feeding hoppers should be kept equal, the particles accumulated on the two feeders are similar, and the particles can be evenly fed into the mold inside the hole. Blockage of feeding hopper or feeder: When pressing tablets, if the particles used are small, viscous or wet, and there are occasional cotton yarn ends and foreign matter in tablets mixed in the particles, the flow is not smooth, so that the particles added to the die hole will be reduced and affect the tablet quality. If the weight of the tablet suddenly decreases, stop and check immediately. Tablet weight changes caused by granules: too wet granules, too much fine powder, too large difference in granule thickness, and insufficient lubricant in granules can also cause changes in tablet weight differences, and the quality of granules should be improved. The reason for the change in tablet weight is generally caused by the failure of the or negligence in work. Therefore, during the tablet pressing process, the maintenance of the machine parts should be done well, and the machine parts should be checked in detail for damage. (10-20 minutes) Weigh the slices once, and the slices coincide with the regulations. The above is the industry sharing brought to you by Lvyi Rotary Tablet Press, I hope you will like it. More about candy , soft water salt , powder , effervescent , chicken bouillon , health product , please pay attention to us, and keep abreast of the latest industry trends!

One increasingly popular managerial tactic to improve problem-solving performance of CUSTOM SOLUTION SERVICES is to increase the connectedness, or what academics call clustering, of the organization

extraction machine are the in thing today. To buy a for yourself do visit SUZHOU PHARMA MACHINERY CO.,LTD. at PHARMA MACHINERY.

As the full potential of extraction machine lies in , the demand for is increasing globally, and is being adopted across the global market.

The value you get from watching how SUZHOU PHARMA MACHINERY CO.,LTD. operates and runs our company and the potential mentorship you would get from us will go a long way towards helping customers understand our company.

SUZHOU PHARMA MACHINERY CO.,LTD., a manufacturer of CUSTOM SOLUTION SERVICES, might emphasize less hassle or less wasted time rather than emphasizing reliability or quality.

GET IN TOUCH WITH Us
recommended articles
Project
no data
Contact Us
Telephone: +86-18241958031/
+86-18913598640
Fax: 86-512-65488640
Whatsapp/Wechat: 008618241958031

Notice:
We hereby declare that our company's only legal contact is through the the above email, Any other similar suffix is a scammer email. 
Address: NO.188 xiangwei road, near junction of xiangwei road and chengyang road (the second floor of south building inside of haiji feiyue) Xiangcheng district, Suzhou city, Jiangsu province, China
no data
Copyright © 2025 Suzhou Pharma Machinery Co., Ltd. | Privacy Policy  Sitemap
Contact us
email
whatsapp
contact customer service
Contact us
email
whatsapp
cancel
Customer service
detect