Can you Install the Differential Pressure Gauge for Pharmaceutical Cleanroom?

Main Applications of Differential Pressure Gauges

Air differential pressure gauges are suitable for measuring slight air pressure differences, and are widely used for the detection and indication of micro pressure differences in environments within the pharmaceutical and microelectronic industries. They can be installed on the outer wall of cleanrooms in either recessed or wall-mounted modes, require no power supply, and feature high sensitivity and relatively high measurement accuracy.

Measurement Modes

Positive Pressure Measurement: Connect the pressure source to any one of the two high-pressure ports with an air guide tube, and plug the unused port; leave one or both low-pressure ports open to the atmosphere.

Differential Pressure Measurement: Connect the high-pressure source to any one of the two high-pressure ports, and the low-pressure source to any one of the two low-pressure ports with air guide tubes respectively; plug the two unused pressure tapping ports on the gauge.

Negative Pressure Measurement: Connect the pressure source to any one of the two low-pressure ports with an air guide tube, and plug the unused port; leave one or both high-pressure ports open to the atmosphere.Can you Install the Differential Pressure Gauge for Pharmaceutical Cleanroom?  1

Installation Requirements for Differential Pressure Gauges

A 2mm thick 304 stainless steel mounting panel for differential pressure gauges can be optionally equipped. After installation, there are no exposed components, resulting in an aesthetic overall appearance and convenient installation and maintenance.

Differential pressure gauges are generally used to detect the pressure difference between cleanrooms and non-clean areas, and are typically installed on the wall separating cleanrooms from non-clean areas, so that the pressure difference between the interior and exterior of the cleanroom can be easily observed from the outside.

Pointer-Type Differential Pressure Gauge Installation Steps

  1. The gauge shall be installed vertically to the horizontal plane of the air purification project.
  2. The measuring point and the gauge installation position shall be at the same horizontal level; otherwise, correction for additional height errors shall be considered.
  3. The distance between the gauge installation position and the measuring point shall be as short as possible to avoid delayed indication.
  4. Ensure complete airtightness with no leakage.
  5. Newly purchased pressure measuring instruments must undergo metrological verification before installation and use, to prevent accuracy damage caused by vibration, damage or other factors during transportation.

Installation Location of Differential Pressure Gauges

Generally, differential pressure gauges should be installed in lower-classification areas, with air tubes leading to higher-classification areas. Typical installation locations include:

  • Between filling areas and corridors;
  • Between clean areas and general areas;
  • Between higher-grade clean areas and lower-grade clean areas.

Key Installation Notes

Differential pressure gauges shall be installed at all locations with different clean classifications to prevent cross-contamination.

  • Pressure indicating devices must be installed at positions with air flow between clean areas and non-clean areas, as well as between different clean classifications, such as openings for conveyor belts.
  • Differential pressure gauges shall also be installed on both sides of the primary and medium-efficiency filters of the air conditioning system, to monitor the integrity and blockage status of the filters.

The set pressure difference should not be excessively high, as it will lead to high energy consumption. For engineering practice, it is recommended that the pressure difference of Grade A areas be maintained at around 60 Pa, and shall not exceed 100 Pa.

  • Pressure Difference Regulation
  • Pressure difference regulation shall start from the innermost room, i.e., the pressure difference of the highest-grade area is determined first, and gradually decreases towards the peripheral areas.
  • Pressure difference indicating and monitoring devices shall be installed between the aseptic dispensing room and the general-area visiting corridor.

 

Suzhou Pharma Machinery Co.,Ltd.

2026/03/23

Gino

prev
Understanding the Importance of Turnkey Cleanroom Projects
no data
Get in touch with us
Contact Us
Telephone: +86-18241958031/
+86-18913598640
Fax: 86-512-65488640
Whatsapp/Wechat: 008618241958031

Notice:
We hereby declare that our company's only legal contact is through the the above email, Any other similar suffix is a scammer email. 
Address: NO.188 xiangwei road, near junction of xiangwei road and chengyang road (the second floor of south building inside of haiji feiyue) Xiangcheng district, Suzhou city, Jiangsu province, China
no data
Copyright © 2026 Suzhou Pharma Machinery Co., Ltd. | Privacy Policy  Sitemap
Contact us
whatsapp
Contact customer service
Contact us
whatsapp
cancel
Customer service
detect