Air conditioning system is a control system containing temperature, humidity, air cleanness and air circulation, which is known as HVAC (Heating,ventilation, air-conditioning and cooling). The HVAC system uses the refrigerant to evaporate or condense under the action of the compressor, thus causing the evaporation or condensation of the surrounding air, so as to change the temperature and humidity.
The rotary dehumidification air conditioning unit can achieve 5%-90% humidity control. The air conditioning system is a control system that includes temperature, humidity, air cleanliness and air circulation. The principle of air conditioning to supply cold air, heat or dehumidification is similar, using the refrigerant to evaporate or coagulate under the action ofl the compressor, thus triggering the evaporation or condensation of the surrounding air to achieve the purpose of changing the temperature and humidity.HVAC refers to an application subject, which has a wide impact on the design and engineering of the world andl the manufacturing industry. All countries have the HVAC Association, and the China Architecture Society HVAC branch is the official representative of China. The basic theoretical basis of heat transfer, engineering thermodynamics and hydromechanics is to provide al more comfortable work and living environment for human beings
Various installation forms: According to the site conditions, a variety of unit forms can be designed to facilitate installation.
It can be divided into horizontal, vertical,ceiling,etc.
Mixing of fresh air and return air: According to the field use conditions,the equipment can be connected with outdoor fresh air, indoor return air, or mixed with fresh air and return air.
Stable,reliable and practical: The panel of the unit adopts polyurethane foam panel as a whole, with high overall strength,good thermal insulation performance,excellent sound insulation performance and low air leakage rate.
Multiple functional sections meet the requirements: A variety of functional sections such as high-efficiency filtration,ozone,electrode humidification and reheating can be selected by users to meet different purification requirements.
Technical Parameters
PH-Series-Roof Top HVAC | 10 | 15 | 18 | 20 | 25 | 30 | 35 | ||
Specification | Cooling capacity | KW | 10.5 | 15.0 | 18.5 | 21.0 | 26.3 | 29.8 | 35.0 |
Heating capacity | KW | 11.5 | 15.9 | 19.5 | 22.1 | 27.6 | 32.6 | 37.1 | |
Supply air | m³/h | 1800 | 2400 | 2900 | 3500 | 4500 | 5000 | 5800 | |
Static pressure | Pa | 100 | 150 | 150 | 180 | 200 | 250 | 250 | |
Noise | dB | 60 | 60 | 62 | 62 | 65 | 65 | 68 | |
Power | 3N-380V-60HZ | ||||||||
Total capacity | 3.9 | 5.74 | 7.0 | 8.27 | 9.96 | 11.0 | 14.15 | ||
Color | White | ||||||||
Cooling system | Compressor | Type | Efficient scroll closed | ||||||
Quantity | 1 | 1 | 1 | 1 | 1 | 1 | 2 | ||
Supply air fan | Type | Low noise centrifugual type | |||||||
Capacity (KW) | 0.37 | 0.55 | 0.75 | 0.75 | 1.1 | 1.5 | 2.2 | ||
Evaporator | Type | Inner grooved copper tube and aluminum fin | |||||||
Fin Type | Slotted fin hydrophilic aluminum fin | ||||||||
Condenser | Type | Inner grooved copper tube and aluminum fin | |||||||
Fin Type | Rippled fin hydrophilic aluminum fin | ||||||||
Condenser fan | Type | Low noise axial type | |||||||
Quantity | 1 | 1 | 1 | 1 | 1 | 1 | 2 | ||
Refrigerant | Refrigerant | R417A/ R407C /R404A /R410A /R413A | |||||||
Refrigerant control | External balance type thermal expansion value | ||||||||
Air filter | Initially effect plate filter | ||||||||
Dimensions | L(mm) | 1400 | 1400 | 1600 | 1600 | 1850 | 1850 | 2200 | |
W(mm) | 1050 | 1050 | 1200 | 1200 | 1400 | 1400 | 1800 | ||
H(mm) | 1050 | 1050 | 1050 | 1050 | 1200 | 1200 | 1520 | ||
Weight | kg | 200 | 230 | 260 | 300 | 550 | 600 | 850 |