Before installing the fan in the sterile workshop, the casing and bearing box should be disassembled and the impeller should be removed for cleaning. However, the fan with direct drive may not be disassembled and cleaned. The lubrication and sealing pipelines should be derusted and cleaned. The viscosity of the lubricant filled in the bearing should meet the design requirements, and should not use variable...
Text label: sterile workshop design and installation, sterile pharmaceutical cleanroom fan installation
Aseptic Ventilator Installation
Before installing the fan in the sterile workshop, the casing and bearing box should be disassembled and the impeller should be removed for cleaning. However, the fan with direct drive may not be disassembled and cleaned. The lubrication and sealing pipelines should be derusted and cleaned. The viscosity of the lubricant filled in the bearing should meet the design requirements, and the lubricant containing impurities after deterioration should not be used; clean and check the adjustment mechanism, and make it rotate and adjust flexibly after assembly. The motor in the sterile pharmaceutical cleanroom should be installed horizontally on the sliding seat or fixed on the foundation. The alignment and leveling of the motor should be based on the installed fan. When it is driven by a V-belt, the motor can be adjusted on the sliding rail. The position of the fan should ensure that the centerlines of the two shafts of the fan and the motor are parallel to each other and fixed on the foundation horizontally, and the direction of the slide rail cannot be reversed.
For the fan driven by the V-belt pulley, when installing the motor, in order to ensure that the axes of the motor and the fan are parallel to each other, the pulley on the motor should be aligned so that the center lines of the two pulleys overlap and the V-belt is tightened ;The motor is fixed on the two slide rails of the motor with bolts, be careful not to install the slide rails in the opposite direction, and place the two slide rails parallel to each other and horizontally on the foundation; the motor can be adjusted on the slide rails to make the V-belt The degree of tightness is appropriate. Generally, tap the middle of the installed belt with your hand and bounce slightly, or press your fingers on the two belts, and it is qualified if it can be pressed down by about 2cm. When the coupling connects the fan and the motor, the centerlines of the two shafts should be on a uniform straight line, the allowable deviation of the axial inclination is 0.2‰, and the allowable deviation of the radial displacement is 0.05mm; the purpose of aligning the coupling is to Eliminate the non-concentricity and non-parallelism of the centerline of the fan main shaft and the centerline of the electric drive shaft, otherwise it will cause fan vibration, motor and bearing overheating and other phenomena. Zhongjing Global Purification can provide consulting, planning, design, construction, installation, transformation and other supporting services for sterile workshops and diagnostic reagent workshops.
The small ventilators in the sterile workshop are all directly connected. The pressure roller of the ventilator is directly fixed on the motor shaft, and the casing is directly fixed on the end flange of the motor; the bracket beam is installed on the wall. Not only must have sufficient strength, but also must have sufficient length and dimension, and the two must keep a certain distance from the wall to ensure the convenience of installing and tightening the motor base and the fan outlet flange bolts; after the bracket is firmly installed, place the vibration damping rubber plate on Put it on the beam of the bracket, and align the screw holes of the two. After the fan is lifted above the plane of the beam, make the screw holes of the motor base align with the beam hole and drop, and pass the bolts upward from the beam and put on the nuts. After entering the bolt holes, according to the anti-vibration and anti-return measures selected in the design, finally tighten the nuts diagonally; check the verticality of the air inlet and outlet of the fan with a level again, and turn the fan impeller by hand to make it rotate. It is flexible and must not be rubbed or jammed; the small centrifugal fan is installed on the concrete foundation, after the holes are reserved for the anchor bolts, the anchor bolts are placed in it, and the vibration damping rubber is placed on the foundation plane. slats.
SUZHOU PHARMA MACHINERY CO.,LTD. supports their market leadership with savvy marketing skills to create an prime brand.
Being a performance leader means SUZHOU PHARMA MACHINERY CO.,LTD. will achieve operational excellence, industry-leading customer satisfaction and superior financial performance.
We are making CUSTOM SOLUTION SERVICES available to you at a very low price.
Though the cost of these sustainability initiatives as CUSTOM SOLUTION SERVICES can be high, harnessing the power of an ethical supply chain to appeal to conscientious consumers can be a smart move both ethically and financially.