Focuses On Professional Cleanroom Project And Pharmaceutical Cleanroom Equipment.

Variable air volume terminal device for clean workshop purification project

Variable air volume terminal device for clean workshop purification project

I. The structure of the variable air volume terminal device and the operation of the variable air volume system in the purification project of the clean workshop

1. Structure of variable air volume terminal device

VAVBox is a VAVBox widely used in northern Europe, a semi...

Text label: clean workshop purification project, variable air volume terminal device

Variable air volume terminal device for clean workshop purification project

I. The structure of the variable air volume terminal device and the operation of the variable air volume system in the purification project of the clean workshop

1. Structure of variable air volume terminal device

VAVBox is a VAVBox widely used in northern Europe, which is a terminal device of a semi-centralized air conditioning system.

The variable air volume terminal device is composed of a box, a nozzle, and a regulating valve.

2. Operation of variable air volume system

Variable air volume can better ensure indoor airflow organization than conventional single-channel variable air volume, with higher comfort, and can also be used in low-temperature air supply systems to further reduce the design capacity of the air system; it can also be used on the ceiling Heat from lights, etc., to delay the activation of the reheat system, making it more energy efficient.

When cooling demand decreases, via VAV

The reduction in the total air volume supplied by the Box to the air conditioning area is smaller than the reduction in the primary air volume. This allows the system to operate with a primary air volume as low as 20%, and there is no chance that the sent cold air will quickly sink from the diffuser to the ground without sufficient heat exchange. The minimum air volume ratio of conventional variable air volume systems is usually limited to 50%. This means that VAV systems can be set at lower air flow values, allowing them to function well even at between 20% and 50% of cooling demand, which can save even more energy.

Second, the characteristics of the variable air volume system in the purification project of the clean workshop

When the supply cooling capacity meets the cooling load of the air-conditioned clean room modular, that is, when it works in the cooling mode, the VAV system has the advantages: it is suitable for the low-temperature air supply system with lower air supply temperature; it is similar to the single-channel VAV system. It can ensure that the indoor air is fully mixed and maintain a reasonable airflow organization; it allows the central air conditioner supplying primary air to work with a smaller circulating air volume.

The variable air volume terminal device utilizes the secondary air entering the ceiling from the clean room modular at a high speed of the primary air, adjusts the mixing ratio of the primary air and the secondary air, and sends it into the clean room modular. For the convenience of adjustment, a constant air volume device is installed on the primary air outlet. Reduce, only gradually open the secondary air door to increase the air supply temperature; in order to reduce noise, the static pressure at the primary air outlet is not more than 500Pa; the advantage is that the air outlet can be combined with lighting fixtures, and the indoor lighting heat can be used for reheating Therefore, energy is saved; the initial investment and operating cost of the variable air volume system using the variable air volume terminal device are higher than that of the throttle type.

VAVBox comes in many forms, with ends with rectangular outlet, end with rectangular outlet and built-in reheat coil, and multi-outlet end with built-in reheat coil. VAVBox is suitable for office buildings, clean workshops and other occasions. Since VAVBox does not produce condensed water, this is also a very important feature of this type of device. VAVBox has some advantages that the traditional all-air system does not have, the size of the air duct is reduced, and the space is saved. The disadvantage is that the noise is large and the wind speed control is not easy. Combining VAVBox with automatic control can further improve the control precision and achieve the expected control goal.

VAVBox is a system worth promoting. The use of VAVBox in the air-conditioning system of office and clean workshop purification projects can solve various defects of fan coil units and provide a more comfortable living environment for people's lives.

Maintaining extraction machine is not as easy as it may seem. You have to do plenty of important tasks. So cruel is the truth unless you've got a to help you.

is making its name in professional extraction machine all over the world, and with SUZHOU PHARMA MACHINERY CO.,LTD. taking great care to make an excellent product & actively involved in keeping the industry well-regulated, it's a product that should make its way into your extraction machine.

SUZHOU PHARMA MACHINERY CO.,LTD. also has an extensive line of products as CUSTOM SOLUTION SERVICES.

Apart from this, exhibit myriad extraction machine benefits, like the prevention of extraction machine by enhancing extraction machine.

CUSTOM SOLUTION SERVICES, is an alternative product for extraction machine to investors and consumers who are passionate about our products or services.

GET IN TOUCH WITH Us
recommended articles
Project
Clean Room Pressure Difference Influencing Factors And control Methods
A professional clean room must control the pressure difference to ensure that air flows from clean areas to non clean areas and from high cleanliness areas to low cleanliness areas during normal use, thereby maintaining clean air in the clean room at all times.
In depth Analysis of Sterile Isolators
Aseptic isolators are enclosed spaces composed of rigid and/or flexible barrier materials. They contain an integrated vaporized hydrogen peroxide (VHP) sterilization system, which can repeatedly sterilize the air inside the isolator and effectively exposed surfaces to remove the bioburden.
Clean Room PVC Floor
Cleanroom pvc flooring is a polyvinyl chloride (PVC) material specifically designed for clean room environments. It has a high density and smooth surface.
Thoughts on the Applicability of Laminar Flow Interference Testing in Clean Areas

In clean area management and quality control, laminar flow interference testing has received much attention, and whether it is only applicable to Class A laminar flow remains to be considered.
no data
Contact Us
Telephone: +86-18241958031/
+86-18913598640
Fax: 86-512-65488640
Whatsapp/Wechat: 008618241958031

Notice:
We hereby declare that our company's only legal contact is through the the above email, Any other similar suffix is a scammer email. 
Address: NO.188 xiangwei road, near junction of xiangwei road and chengyang road (the second floor of south building inside of haiji feiyue) Xiangcheng district, Suzhou city, Jiangsu province, China
no data
Copyright © 2025 Suzhou Pharma Machinery Co., Ltd. | Privacy Policy  Sitemap
Contact us
email
whatsapp
contact customer service
Contact us
email
whatsapp
cancel
Customer service
detect