Focuses On Professional Cleanroom Project And Pharmaceutical Cleanroom Equipment.

Testing laboratory planning and design

Testing laboratory planning and design

office area, production test area, living and living area, supporting service area, external reception area and other areas should be set up separately, and the connection is convenient and does not interfere with each other; when they are built in the same area, they should be separated from each other, and the other Set up entrances and exits, and should comply with relevant norms and regulations. From testing real...

Text label: testing laboratory design, pharma machinery planning and installation

Planning and Design of Testing

office area, production test area, living and living area, supporting service area, external reception area and other areas should be set up separately, and the connection is convenient and does not interfere with each other; when they are built in the same area, they should be separated from each other, and the other Set up entrances and exits, and should comply with relevant norms and regulations. From the perspectives of testing laboratory system management, functional layout, safety prevention and control, etc., to ensure the safety of laboratory technicians, samples, data, instruments and the environment, and to ensure the authenticity and reliability of experimental data and test results; fully demonstrate the characteristics of the laboratory On the basis of the laboratory system, the engineering design of the laboratory system should be optimized, the three wastes should be properly handled, and the energy saving, water saving, low carbon and environmental protection should be achieved as much as possible.

Layout of testing laboratory room: independent, the entire building configuration is concentrated in one building and set up independently, suitable for smaller laboratories; main building type, with a laboratory building as the main building The planning is relatively square and regular; the decentralized type is composed of multiple experimental buildings, research buildings and auxiliary buildings with different functions, and many are used; Different spaces are conducive to the realization of building modularization and standardization, which is convenient for construction. The overall layout of the laboratory mainly includes the core area of u200bu200bthe laboratory, the auxiliary area and the public facility area. The core area includes the experimental work area, the experimental buffer area, the sample preparation area, the sample receiving room, the sample storage room, etc.; the auxiliary area includes the business reception room, data File storage room, equipment accessories room, office, conference room, etc.; public facilities area includes HVAC, air conditioning, water supply and drainage, special gas, special water, power supply and distribution, telecommunications and other rooms. The distribution of building planning area is generally 50%-90% of the core area, 5%-32% of the auxiliary area, and 5%-18% of the public facilities. If the overall layout of the laboratory is decentralized, it is advisable to distinguish the experimental area from the business reception room, office, conference room, etc., and the equipment accessories room and the public facilities area can be placed between the two. For example, different types of laboratories are concentrated in one building. The vertical layout of the building should be considered comprehensively, such as arranging the vibration laboratory on the ground floor of the building, and arranging the laboratory that may cause pollution on the upper floor of the building; for example, when the business, experiment and assurance areas are concentrated in one building, the experiment area should be placed in the upper part of the building. Zhongjing Global Purification can provide consulting, planning, design, construction, installation, transformation and other supporting services for testing laboratories and sterile laboratories.

The range of the plane coefficient of the laboratory is usually between 50%-70%. The overall setting of the chemical, biological and physical laboratories is relatively simple. The range of the plane coefficient is usually between 60% and 65%. Pipe shafts are set. In the laboratory, the plane coefficient is usually 60%. Due to the large number of auxiliary facilities in the testing laboratory, the plane coefficient is usually 55%-60%, and the plane coefficient of individual special laboratories will be lower than 55%. The net height of the clean laboratory itself is lower than that of the general laboratory. This is because the clean laboratory saves air-conditioning cooling capacity and adopts artificial lighting. Generally, the net height is about 2.5m, and the computer room is based on the size of the plane space. It is generally 2.4m-3m; the ground floor needs to be equipped with large-scale equipment, and the height of the solid floor is slightly higher than that of the floor. The floor heights of special laboratories, such as accelerator laboratories and reactor laboratories, are determined according to process requirements; the floor heights of general chemistry, physics, and biology laboratories are recommended to be 3.6m-3.9m, and the indoor clear height of conventional laboratories is recommended. When air conditioning is not set, it should not be lower than 2.8m; when air conditioning is set, it should not be lower than 2.4m. The aisle purification should not be lower than 2.2m.

CUSTOM SOLUTION SERVICES are among the best and the long known , which plays an essential part in automatic manufacturing.

Reach us at PHARMA MACHINERY. We'll always try to give you the BEST deal on . If we can't, we'll at least give you some hel pful advice. Please use our experience!

First, in sparking the initial idea for a company based on manufacturing technology; and second, in designing a solution that could meet a clear market need for solving issues related to CUSTOM SOLUTION SERVICES extraction machine.

An easy and inexpensive CUSTOM SOLUTION SERVICES solution can be easily obtained now through purchasing a CUSTOM SOLUTION SERVICES extraction machine online. Find your solution at PHARMA MACHINERY, your demand will be satified.

GET IN TOUCH WITH Us
recommended articles
Project
Clean Room Pressure Difference Influencing Factors And control Methods
A professional clean room must control the pressure difference to ensure that air flows from clean areas to non clean areas and from high cleanliness areas to low cleanliness areas during normal use, thereby maintaining clean air in the clean room at all times.
In depth Analysis of Sterile Isolators
Aseptic isolators are enclosed spaces composed of rigid and/or flexible barrier materials. They contain an integrated vaporized hydrogen peroxide (VHP) sterilization system, which can repeatedly sterilize the air inside the isolator and effectively exposed surfaces to remove the bioburden.
Clean Room PVC Floor
Cleanroom pvc flooring is a polyvinyl chloride (PVC) material specifically designed for clean room environments. It has a high density and smooth surface.
Thoughts on the Applicability of Laminar Flow Interference Testing in Clean Areas

In clean area management and quality control, laminar flow interference testing has received much attention, and whether it is only applicable to Class A laminar flow remains to be considered.
no data
Contact Us
Telephone: +86-18241958031/
+86-18913598640
Fax: 86-512-65488640
Whatsapp/Wechat: 008618241958031

Notice:
We hereby declare that our company's only legal contact is through the the above email, Any other similar suffix is a scammer email. 
Address: NO.188 xiangwei road, near junction of xiangwei road and chengyang road (the second floor of south building inside of haiji feiyue) Xiangcheng district, Suzhou city, Jiangsu province, China
no data
Copyright © 2025 Suzhou Pharma Machinery Co., Ltd. | Privacy Policy  Sitemap