Special Electrical Requirements
The special electrical laboratory should be equipped with a control room, an equipment room and a general stacking area. The control room should be close to the auxiliary door, where antenna control, turntable control and receivers can be placed. The equipment room is mainly used for power amplifiers, loads and other equipment. The room can be arranged on the next floor of the dark room ground floor, try to...
Text label: special electrical laboratory, laboratory design, installation and renovation
Special Electrical Requirements
The special electrical pharma machinery should be equipped with a control room, an equipment room and a general stacking area. The control room should be close to the auxiliary door, where antenna control, turntable control and receivers can be placed. The equipment room is mainly used for power amplifiers, loads and other equipment. The chamber can be arranged on the next floor of the darkroom ground floor, as close as possible to the antenna tower. Generally, the stack area is used to place movable test facilities such as absorbing materials, and should be kept away from heat sources. It is advisable to choose the lowest floor of the building or build it as a single building. The size of the site should be determined according to the type of darkroom and the product range tested in the darkroom. Space should be reserved for the installation and maintenance of lighting, air-conditioning, power distribution and other facilities on the top of the dark room and the top of the dark room. The dark room usually needs to be dug down, and the ground beams should be reinforced within the excavated space; special products The darkroom used should consider the installation area of u200bu200bthe hub system. If necessary, the basement of the darkroom area should be occupied. At this time, suitable windows should be reserved on the ground floor and basement of the darkroom for the connection of cables such as signal lines and power lines. ; There should be at least one passageway with a width of 1.8m and no steps between the outside of the building and the darkroom area; the load-bearing requirements should be considered according to the darkroom structure, different load areas, equipment placement and test sample range.
When the darkroom door is closed in a non-manual way, there should be a warning device in the process of closing, and it should be placed at the door of the darkroom to display the operating status of the darkroom. Monitoring cameras should be installed in the equipment room, power supply and load area; it is used for high-strength testing. There should be sufficient safety protection measures in the darkroom, and the test system and the darkroom should have the function of interlocking. It is set that the formal test can only start after the doors of the darkroom are all closed. The emergency stop switch button should be set in the control room. Radiation can be turned off immediately in the event of an outbreak. The anechoic room ventilation should pass through the waveguide windows that meet the requirements. The control range of the anechoic room environment should be determined according to the standards of the test products. The air conditioning and cooling in the anechoic room can be considered as the downward air supply mode. Often used to detect products that generate exhaust gas, an exhaust gas treatment system should be installed, and the intensity of ventilation should be increased. According to the range of products used in the darkroom, determine whether the darkroom has the function of water supply and drainage. There should be drainage ditch around the darkroom in the form of an underdrain. The drainage point should be set up in an appropriate position, and the surrounding ground should be sloped towards the drainage point. The darkroom should be equipped with 380V/50Hz three-phase power supply and 220V/50Hz single-phase power supply. If necessary, it can be equipped with voltage and frequency adjustable power supply. The power supply in the darkroom should be connected after passing through the filter, and there should be enough protection switches in front of the filter. Zhongjing Global Purification can provide consulting, planning, design, construction, installation, transformation and other supporting services for laboratories and special electrical laboratories.
During the design and construction of the special electrical pharma machinery, a strict waterproof scheme should be formulated to address all possible water erosion, such as the setting of doors and windows, indoor water supply and drainage systems, air-conditioning water systems, rainwater drainage systems, toilets, Groundwater and other measures should be taken. A flat and easy-to-clean building decoration scheme should be adopted as much as possible to minimize the hidden dust in the structural support system and reduce the impact of dust; the concrete in the anechoic room area should be treated with moisture-proof, and all joints between the anechoic chamber and the building floor should be moisture-proof and anti-corrosion. Treatment; the relative flatness of the floor of the darkroom parent room is within 5mm/5m, and the absolute flatness does not exceed 5mm. Considering factors such as load-bearing, sample handling and installation, the enthalpy difference laboratory should be built on a lower floor, and the first floor is the most suitable; the water-cooled cooling tower is noisy and should be installed outdoors; the enthalpy difference laboratory is indoor and outdoor. Observation glass windows should be set up, and its size width*height should not be less than 0.4m*0.3m; the testing operation area of u200bu200bthe laboratory should be provided with sufficient illumination, and the illumination should not be lower than 250Ix. The samples must be pretreated before the test. The room should be able to meet the environmental temperature requirements of 20±5℃, the temperature gradient should be less than 2℃/m, and the control room should be equipped with a heating and cooling air conditioner of 2.5KW or more. The enthalpy difference laboratory should have compressed gas. If gas can be centrally supplied, it should be designed and constructed according to the requirements of central gas supply.
SUZHOU PHARMA MACHINERY CO.,LTD. is deemed as one of the leading provider of CUSTOM SOLUTION SERVICES products in China.
We want to continue to organize PHARMA to make it more efficient and profitable so that both, our clients and our employees can get more out of their time.
SUZHOU PHARMA MACHINERY CO.,LTD. might focus its marketing efforts by highlighting its end product—improved technology and increased profits—not its producing methods.