Precautions when adjusting tablet

The machine can only run in the direction marked on the motor cover, and cannot be reversed to avoid damage to the machine. Special attention should be paid to the adjustment of the tablet compression pressure, which cannot be ignored. Whether it is manual pressure or electric pressure, the upper punch should be in the upward position before starting, and then restart. If the upper punch is started at the down position, the upper punch will enter the middle mold to press the sheet immediately after starting. At this time, due to the low speed of the machine and poor dragging ability, jacking is prone to occur. Happening. (That is, after the upper punch enters the middle mold, the machine will stop due to the resistance of the tablet pressing. Due to the large load during the jacking, the machine will