Optical laboratory construction requirements? -common problem

Optical laboratory construction requirements?

The selection of the optical pharma machinery site mainly considers the type of products to be measured and the type of equipment. For the types of products with large measurement size and large luminous output, it is advisable to choose the lowest floor of the building or a separate building, or you can choose to Each floor, but should carefully consider equipment installation, space...

Text label: optical laboratory, laboratory construction requirements

Optical pharma machinery construction requirements?

The selection of the optical laboratory site mainly considers the type of products to be measured and the type of equipment. For the types of products with large measurement size and large luminous output, it is advisable to choose the lowest floor of the building or a separate building, or you can choose to For each floor, the factors of equipment installation, space size and load-bearing should be considered in detail, and the size of the site should be determined according to the type of optical darkroom and the scope of test products; it should be kept as far away as possible from the building machine room, vehicle entry and exit passages, vibration laboratories and sources of electromagnetic infection. The optical darkroom of the light distribution measurement system should have a main door and a secondary door. The main door has a larger size and is used for the entry and exit of the measurement equipment during installation and the entry and exit of large samples during normal measurement. The size should be considered according to the type of measurement equipment. The size should be larger than the main door of the darkroom, and the outer wall door, the main door of the darkroom and the main equipment are on the same line; the secondary door is used for personnel and small samples to enter and exit, and the size can be considered according to needs. It should be equipped with a control observation room, an equipment room and a general stacking area. The control observation room should be close to the secondary door, where control and receiving equipment, computers and other equipment can be placed. The control observation room and the equipment room are merged into the control equipment observation room, which is as close as possible to the main equipment.

Space should be reserved at the top of the optical darkroom for the installation and maintenance of lighting, air conditioning, power distribution and other facilities. For the optical darkroom on the ground floor with a low floor height where large light distribution equipment is placed, the main equipment area during construction Usually, it is necessary to dig down space, and the beams should be reinforced within the scope of the digging space; the load-bearing requirements should be considered according to the optical darkroom structure, different load areas, the placement of equipment and the range of samples tested, and the flatness of the concrete floor within the darkroom area should be considered. Not more than 5mm/5m, and the influence of land subsidence should also be considered. The ventilation of the optical darkroom should meet the requirements, and the control range of the environment should be determined according to the standards of the test products. The air conditioning and cooling in the darkroom can be considered as the upper and lower air supply mode. The intensity of the ventilation of the optical darkroom should consider the scope of the tested products; it should be equipped with 380V/50Hz Three-phase power supply and 220V/50Hz single-phase power supply can be equipped with voltage and frequency adjustable power supply if necessary. The power supply in the dark room should be connected after passing through the filter. There should be enough protection switches in front of the filter. The power supply capacity should consider the power consumption of the equipment. About 5KV.A, the power consumption of the sample should be based on the maximum capacity of the sample to be tested in the laboratory, and the air-conditioning power should be comprehensively considered according to the size of the darkroom space and the load of the test product. In the case of ensuring that the installation samples or maintenance equipment can be seen clearly, the optical dark room lighting should minimize the lighting fixtures and the outer surface of the fixtures to avoid stray light caused by the reflection of the fixtures. The exterior of the lighting fixtures should be painted with matt black paint, etc. Power flood light, and after installing the sample to be tested, it can be easily adjusted to cover the lamp with black velvet cloth. Zhongjing Global Purification can provide consulting, planning, design, construction, installation, transformation and other supporting services for optical laboratories and clean laboratories.

A plan that is flat and easy to clean should be adopted as much as possible to minimize the hidden dust in the structural support system and reduce the impact of dust. In the process of design and construction, a strict waterproof plan should be formulated to address all possible water erosion, such as doors and windows. Position setting, indoor heating water, water supply and drainage system, air-conditioning water system, toilet, groundwater, etc. should be targeted measures, the concrete in the optical darkroom area should be moisture-proof, and all the joint parts of the darkroom and the building ground should be moisture-proof and anti-corrosion. Treatment; the relative flatness of the floor of the parent room of the optical darkroom should be within 5mm/5m, and the absolute flatness should not exceed 5mm. In the measurement environment where the temperature near the tested sample is stable at 25±1℃, the maximum relative humidity is 65% without convection, and the air pressure is 86KPa-106KPa, an air conditioning cooling or heating system should usually be installed. In order to achieve this condition, circulating air may be required, but The wind speed near the sample should not exceed 0.2m/s. In order to reduce the power consumption of the air conditioner, the irrelevant space can be minimized, and the main equipment head is mainly adjusted and stabilized.

SUZHOU PHARMA MACHINERY CO.,LTD. has various branches in different countries worldwide.

To receive more professional tips and super quality products for extraction machine, go to our website PHARMA MACHINERY to place your order. Do not wait any longer.

To deal with commercial threats, SUZHOU PHARMA MACHINERY CO.,LTD. konws that the notion of proactively seeking out potential or looming external threats against a company is gaining traction.

SUZHOU PHARMA MACHINERY CO.,LTD., which contributes itself on CUSTOM SOLUTION SERVICES for creating more useful application.

SUZHOU PHARMA MACHINERY CO.,LTD. is the best manufacturer which has rich experience on manufacturing.

GET IN TOUCH WITH Us
recommended articles
Project
no data
Contact Us
Telephone: +86-18241958031/
+86-18913598640
Fax: 86-512-65488640
Whatsapp/Wechat: 008618241958031

Notice:
We hereby declare that our company's only legal contact is through the the above email, Any other similar suffix is a scammer email. 
Address: NO.188 xiangwei road, near junction of xiangwei road and chengyang road (the second floor of south building inside of haiji feiyue) Xiangcheng district, Suzhou city, Jiangsu province, China
no data
Copyright © 2025 Suzhou Pharma Machinery Co., Ltd. | Privacy Policy  Sitemap
Contact us
email
whatsapp
contact customer service
Contact us
email
whatsapp
cancel
Customer service
detect