Focuses On Professional Cleanroom Project And Pharmaceutical Cleanroom Equipment.

Layout planning of testing and inspection laboratories

Layout planning of testing and inspection laboratories

The layout of the testing laboratory includes embedded type, adjoining type and separate type. Usually, the testing laboratory does not have a special research room, but if you need to set it up, you can refer to the following forms. Inclusion type: The laboratory and the research room are in one room, and the desk is set in the laboratory...

Text label: testing laboratory layout, testing laboratory planning and design

Layout planning of testing pharma machinery

The layout of the testing laboratory includes embedded type, adjoining type and separate type. Usually, the testing laboratory does not have a special research room, but if you need to set it up, you can refer to the following forms. Included type: The laboratory and the research room are in the same room, and the desk area or research room is set up in the laboratory. This form of laboratory and research room is convenient to connect, the depth of the laboratory is larger, the land is saved, and the pipeline layout is more economical , but the laboratory has a certain influence on the research laboratory. There are various forms of adjoining plane layout. The research room and the laboratory are separated by a corridor or in one-to-one correspondence, or the research room is arranged along one side of the large space laboratory, or it can be arranged on both sides. The separation-type laboratory is arranged separately from the pharma machinery, the pipeline layout is economical and reasonable, and the laboratory has little impact on the laboratory. Some laboratories have stricter temperature requirements, and the research room is arranged around the laboratory, such as the high-purity analysis room. Get natural lighting in the perimeter, etc.

There are many forms of separation in the laboratory. In addition to ordinary partition walls, test racks, fume hoods, test benches, and test cabinets can be used to separate the test space. Commonly used partitions are aluminum alloy partitions, which can be used according to sound insulation requirements. Single-layer or double-layer large glass; a transparent partition is used between the laboratory and the research room, which can improve the working environment of the research room and enable researchers to observe the working conditions in the laboratory; the large-space pharma machinery adopts flexible partitions, The large space can be separated freely and flexibly, and the position of the partition can be changed. The partition is composed of removable components. The partition can be connected to the ceiling or the ground respectively, or it can be connected to the ground and the ceiling at the same time. Zhongjing Global Purification can provide consulting, planning, design, construction, installation, transformation and other supporting services for testing laboratories and GMP laboratories.

Pipelines can use the reserved hole components on the floor. The holes on the floor can be flexibly designed in advance according to the needs. The reserved hole components are installed on the floor according to the size of the building module. It consists of a cover and a lower cover. When the pipeline needs to pass through, just open the upper and lower covers. This method not only ensures the integrity of the ground inside the laboratory, but also achieves the purpose of convenient pipe penetration. A laboratory with additional experimental equipment is an ideal flexible component. Set up trenches along the horizontal or longitudinal direction of the building, and guide the pipeline to the test bench through the trenches. The cover of the trenches should be made into movable cover, and a few aluminum plane handles should be installed to facilitate opening. The design of the trench itself should take into account Discharge of leaking waste liquid to prevent pipeline corrosion. The anti-static raised floor has the characteristics of anti-static and great flexibility. It is composed of accessories such as supports, small beams and raised floors. Metal supports are installed on the ground according to the size of the raised floor, and there are bolts on the metal supports that can be adjusted. Height, the upper part is installed with metal small beams, and the raised floor is placed on it, which can be opened at will, and the cables and pipelines can be arbitrarily arranged in the space under the raised floor.

It isn't just about being on CUSTOM SOLUTION SERVICES anymore–it's about maximizing the potential of the platform of manufacturing.

Do you want extraction machine CUSTOM SOLUTION SERVICES? We also have extraction machine. visit PHARMA MACHINERY to know more.

The more people who do a certain thing, the more likely others are to do it as well. When PHARMA can demonstrate their popularity or satisfaction across a wide customer base, other consumers are more likely to buy in as well.

GET IN TOUCH WITH Us
recommended articles
Project
Clean Room Pressure Difference Influencing Factors And control Methods
A professional clean room must control the pressure difference to ensure that air flows from clean areas to non clean areas and from high cleanliness areas to low cleanliness areas during normal use, thereby maintaining clean air in the clean room at all times.
In depth Analysis of Sterile Isolators
Aseptic isolators are enclosed spaces composed of rigid and/or flexible barrier materials. They contain an integrated vaporized hydrogen peroxide (VHP) sterilization system, which can repeatedly sterilize the air inside the isolator and effectively exposed surfaces to remove the bioburden.
Clean Room PVC Floor
Cleanroom pvc flooring is a polyvinyl chloride (PVC) material specifically designed for clean room environments. It has a high density and smooth surface.
Thoughts on the Applicability of Laminar Flow Interference Testing in Clean Areas

In clean area management and quality control, laminar flow interference testing has received much attention, and whether it is only applicable to Class A laminar flow remains to be considered.
no data
Contact Us
Telephone: +86-18241958031/
+86-18913598640
Fax: 86-512-65488640
Whatsapp/Wechat: 008618241958031

Notice:
We hereby declare that our company's only legal contact is through the the above email, Any other similar suffix is a scammer email. 
Address: NO.188 xiangwei road, near junction of xiangwei road and chengyang road (the second floor of south building inside of haiji feiyue) Xiangcheng district, Suzhou city, Jiangsu province, China
no data
Copyright © 2025 Suzhou Pharma Machinery Co., Ltd. | Privacy Policy  Sitemap
Contact us
email
whatsapp
contact customer service
Contact us
email
whatsapp
cancel
Customer service
detect