Focuses On Professional Cleanroom Project And Pharmaceutical Cleanroom Equipment.
1. Control of tablet thickness and compaction degree The dosage of the drug is determined according to the prescription and pharmacopoeia and cannot be changed. In order to meet the requirements of storage, storage and disintegration time limit, there is also a requirement for a certain dose of pressure during tablet compression, which will also affect the actual thickness and appearance of the tablet. The pressure adjustment is essential when pressing the tablet. This is achieved by adjusting the downward movement of the upper punch in the die hole. Some tablet presses not only have the upper punch and the lower punch during the tablet pressing process, but also have the lower punch. The upward movement of the machine is completed by the relative movement of the upper and lower punches to complete the tablet pressing process. But pressure