5. The feeder is damaged

1.Fault condition:Collide with undershoot

Cause of failure:(1) the out sheet is not adjusted properly, and the down punch is higher than the plane of the middle die(2) the fixed screw of the lower punch is loose, and the lower punch rises out of the plane of the middle die

Fault prevention and treatment:When installing and adjusting the die, pay attention to the looseness of the screw. Immediately press the die to the bottom and tighten the fixing screw.


2.Fault condition:Collide with the lower part of the middle mold

Cause of failure:The fixing screws of the middle mold are loose, and the middle mold rises out of the plane of the middle mold bedplate.

Fault prevention and treatment:When installing and adjusting the die, pay attention to the looseness of the screw. Immediately press the die to the bottom and tighten the fixing screw.


3.Fault condition:Damaged by the upper impact

Cause of failure:(1) reverse rotation and collision during adjustment(2) when adjusting, the position of the upper punch rod is too low, and the rotation of the hand wheel causes collision

Fault prend treatvention ament:Attention during adjustment

 

Suzhou Pharma Machinery Co., Ltd a manufacturer integrating design, production and installation, introduces advanced production lines, and can design and produce according to customer requirements. Make products with the spirit of craftsmanship of excellence.The product quality is guaranteed and the service is perfect. The manufacturer's direct sales saves you intermediate costs.we can provide you with a full set of pharmaceutical production lines and clean room construction, and provide you with one-stop service. It is your trusted partner. Welcome to cooperate with Suzhou Pharma machinery for win-win!

 

news-PHARMA-img
news-Feeder damage of common faults of single tablet press machine-5-PHARMA-img                 
news-PHARMA-Feeder damage of common faults of single tablet press machine-5-img                 

Suzhou Pharma Machinery Co.,Ltd.

2022/05/01

Mia


prev
Example Of Purification Design Requirements For Hospital Clean Operating Room, Comprehensive And Detailed.
The Purpose Of Clean Room Testing.
next
recommended for you
no data
GET IN TOUCH WITH Us
Contact Us
Telephone: +86-18241958031/
+86-18913598640
Fax: 86-512-65488640
Whatsapp/Wechat: 008618241958031


Notice:
We hereby declare that our company's only legal contact is through the  Email pharma@sz-pharma.com, Any other similar suffix is a scammer email. 


Address: NO.188 xiangwei road, near junction of xiangwei road and chengyang road (the second floor of south building inside of haiji feiyue) Xiangcheng district, Suzhou city, Jiangsu province, China
no data
Copyright © 2024 Suzhou Pharma Machinery Co., Ltd. | Sitemap
Customer service
detect