Emission reduction measures for clean pharmaceutical cleanroom supporting air-conditioning cold source environment
Choose natural cold source or clean renewable cold source as much as possible for the air-conditioning cold source environment of clean workshops, so as to prevent the emission of pollutants from the source; when selecting conventional air-conditioning cold source refrigeration equipment and refrigerants, it is necessary to be efficient, energy-saving and environmentally friendly; During the operation and use phase, it must be...
Text label: Clean pharmaceutical cleanroom supporting air-conditioning cold source environment, emission reduction measures
Emission reduction measures for air-conditioning and cold source environment in clean workshops
Choose natural cold source or clean renewable cold source as much as possible for the air-conditioning cold source environment of clean workshops, so as to prevent the emission of pollutants from the source; when selecting conventional air-conditioning cold source refrigeration equipment and refrigerants, it is necessary to be efficient, energy-saving and environmentally friendly; During the operation and use stage, it is necessary to strengthen the maintenance management and strictly follow the operating procedures to avoid leakage. The temperature of the air-conditioned room will not rise immediately because the air conditioner is turned off. Turn off the air conditioner 3 minutes before going out. According to the estimate that each unit can save about 5KW.h of electricity, the corresponding emission reduction of carbon dioxide is 4.8kg; when the cold source system adopts piston compression refrigeration Machine refrigeration, and when ammonia compression refrigeration is used, emergency ammonia leaker auxiliary equipment is required, and the equipment can discharge ammonia liquid to the outside of the refrigeration room in an emergency.
Actively repair and maintain the air-conditioning cold source. Common faults of the air-conditioning cold source include: leakage of refrigerant or electrical insulation damage caused by electrical leakage; dirty and ice blockage of the refrigeration system; electrical circuit disconnection, caused by abnormal pressure in the refrigeration system The pressure relay is disconnected by electric shock; the compressor is stuck, the fan is stuck, etc.; the compressor valve plate is damaged, the piston is scratched and various parts are damaged. In daily use, repair and repair the air-conditioning cold source in a timely manner, and carefully check whether the pipes of the refrigeration system are cracked, damaged, frosted and dew condensation, etc. There is no friction between each other, especially the welding of the refrigerant pipeline, whether there is leakage at the connection of the screenshots, and if there is oil in the leakage, you can use a clean rag or soft paper to wipe the welding of the pipeline and the joint connection, and check whether there is oil. to determine if there is a leak. Compression condensation is to use a compressor to increase the pressure of gaseous refrigerant, and then cooled by a condenser to liquefy the refrigerant and store it in a recovery container. After the refrigerant vapor in the recovery system is dried and filtered, it enters the compressor to be compressed into high-pressure steam, and then enters The condensed gas is cooled. After passing through the gas-liquid separator, the condensed high-pressure liquid refrigerant flows into the recovery container. The oil separator in the system can separate the compressor refrigeration oil mixed in the recovered gas. Compared with the cooling method, its equipment is small in size, Low energy consumption and high efficiency, suitable for the recovery of large and medium capacity refrigerants. Zhongjing Global Purification can provide consulting, planning, design, construction, installation, transformation and other supporting services for clean workshops and sterile workshops.
Air-conditioning refrigerant recovery equipment is mostly based on 'gas recovery-compression methodTake it out and store it in a refrigerant cylinder. The equipment can use a desiccant filter with a removable core to remove water powder, acid, particulate matter and other impurities. Parts with filters are separated, and before opening the filter housing, the refrigerant is moved to a suitable storage cylinder. The recovery equipment is mainly in the form of portable, mobile and vehicle-mounted. The mobile recovery equipment mainly adopts 'gas recovery-cooling method' and 'gas recovery-compression methodRecovery of refrigerant capacity. The vehicle-mounted recovery equipment mainly adopts the 'gas recovery-compression method' and the combined gas and liquid recovery method, which is suitable for refrigerant recovery from small capacity to large capacity.