Focuses On Professional Cleanroom Project And Pharmaceutical Cleanroom Equipment.

Composition and operation of refrigeration station in sterile clean room

Composition and operation of refrigeration station in sterile clean room

The composition of the refrigeration station of the sterile clean room

1. Chiller unit

The chiller is the core equipment of the refrigeration station. The main function of the chiller is to produce and prepare low-temperature chilled water, supply and transport it to remote air-conditioning units, fresh air units, fan coil units, variable air volume air conditioners...

Text label: sterile pharmaceutical cleanroom, clean room, sterile clean room, sterile clean room refrigeration station

Composition and operation of refrigeration station in sterile clean room

The composition of the refrigeration station of the sterile clean room

1. Chiller unit

The chiller is the core equipment of the refrigeration station. The main function of the chiller is to produce and prepare low-temperature chilled water, supply and transport it to remote air-conditioning units, fresh air units, fan coil units, variable air volume air-conditioning units and other terminal equipment. The cold water coils and surface coolers flowing through these terminal equipment cool the air, and then transport the cold air to various air-conditioned sterile clean rooms through the air duct system.

The temperature range of chilled water supplied and transported by the chiller is as follows:

The water supply temperature of air-conditioning chilled water is 5-9°C, generally 7°C; the temperature difference between the supply and return water of air-conditioning chilled water is 5-10°C, generally 5°C.

2. Water distributor and water collector

The main function of the water distributor: the chilled water provided by the different chillers in the refrigeration station is gathered to the water distributor, and then the water distributor provides the cold source to the air-conditioning terminal equipment distributed in different positions through the branch pipeline—— frozen water.

The main function of the water collector: the chilled water flowing back from different air-conditioning terminal devices at the remote end (if the temperature of the chilled water flowing into the air-conditioning terminal is 7°C, the design temperature of the return water is 12°C). Back to the water collector, since the temperature of the return water of the chilled water has increased (a value higher than 7°C, but not more than 5°C), it must flow back to the chiller to continue cooling.

3. Chilled water pump

The main function of the chilled water pump is to provide power for overcoming the damping of chilled water transport. If there is only one level of chilled water pump in the chilled water circuit, this level of chilled water pump is connected to the side of the chilled water return port of the chiller, which is called the first level of chilled water pump; if there are two levels of chilled water pumps in the chilled water circuit, the other water pump Connected to the side of the chilled water outlet of the chiller, it is called a secondary chilled water pump. Zhongjing Global Purification can provide consulting, planning, design, construction, installation and transformation of GMP workshops, purification projects, sterile workshops, clean workshops, laboratories and other supporting services.

4. Cooling water pump and cooling water tower

(1) Cooling water tower.

The condenser in the chiller produces a large amount of heat during operation. This heat is carried away through the cooling water circulation and dissipated into the space through the cooling tower. After absorbing heat from the condenser, the cooling water heats up, and is injected into the cooling tower space through the cooling water inlet pipe, and the cooling tower fan blows the injected cooling water into smaller droplets. The surrounding air undergoes heat exchange, and the temperature decreases and then flows back to the chiller from the cooling water outlet pipe to continue the above-mentioned cooling cycle process.

(2) Cooling water pump. In order to overcome the obstacles of damping and water potential energy encountered in the circulating flow of cooling water, a cooling water pump can be used. In the system structure of the refrigeration station, the cooling water pump is connected to the water outlet side of the cooling tower. In other words, the cooling water pump is connected to the cooling water return side of the chiller.

Operation of refrigeration station in sterile clean room

The method of group analysis can be used when analyzing the working conditions of the refrigeration station. The No. 1 chiller, the No. 1 cooling tower, the No. 1 cooling water pump, and the No. 1 chilled water pump are combined into a group for operation analysis. First, the chilled water circuit of this group is analyzed. water dispenser. The chilled water is separated from the water separator and transported to the remote end of the air conditioner, where heat exchange is performed at the surface cooler at the end, and the temperature rises from the end to flow back to the water collector, and then from the water collector to the chiller. The return port of the chilled water.

Situation of cooling water circuit: The cooling water flowing out from the inside of the chiller absorbs the heating temperature of the condenser and is transported to the top of the cooling tower. The flow enters the chiller for circulating operation.

SUZHOU PHARMA MACHINERY CO.,LTD., the best suppliers of domestic markets, has good faith in manufacturing.

Now you can enjoy extraction machine with SUZHOU PHARMA MACHINERY CO.,LTD.'s latest collection of extraction machine CUSTOM SOLUTION SERVICES products. Do visit now, at PHARMA MACHINERY.

SUZHOU PHARMA MACHINERY CO.,LTD. really created a whole persona around CUSTOM SOLUTION SERVICES’s manufacturing and selling, and it's so innovative that people really respond to it.

But we do think that reckoning with supply chains of CUSTOM SOLUTION SERVICES is a really important step. Even super simple switches in material, or sourcing, or shipping, or worker benefits seems like good place to start.

Getting CUSTOM SOLUTION SERVICES from an idea to production is a complex process. It involves significant research, time, planning and patience. But with the right information, the right resources and the right product, it's possible.

GET IN TOUCH WITH Us
recommended articles
Project
Clean Room Pressure Difference Influencing Factors And control Methods
A professional clean room must control the pressure difference to ensure that air flows from clean areas to non clean areas and from high cleanliness areas to low cleanliness areas during normal use, thereby maintaining clean air in the clean room at all times.
In depth Analysis of Sterile Isolators
Aseptic isolators are enclosed spaces composed of rigid and/or flexible barrier materials. They contain an integrated vaporized hydrogen peroxide (VHP) sterilization system, which can repeatedly sterilize the air inside the isolator and effectively exposed surfaces to remove the bioburden.
Clean Room PVC Floor
Cleanroom pvc flooring is a polyvinyl chloride (PVC) material specifically designed for clean room environments. It has a high density and smooth surface.
Thoughts on the Applicability of Laminar Flow Interference Testing in Clean Areas

In clean area management and quality control, laminar flow interference testing has received much attention, and whether it is only applicable to Class A laminar flow remains to be considered.
no data
Contact Us
Telephone: +86-18241958031/
+86-18913598640
Fax: 86-512-65488640
Whatsapp/Wechat: 008618241958031

Notice:
We hereby declare that our company's only legal contact is through the the above email, Any other similar suffix is a scammer email. 
Address: NO.188 xiangwei road, near junction of xiangwei road and chengyang road (the second floor of south building inside of haiji feiyue) Xiangcheng district, Suzhou city, Jiangsu province, China
no data
Copyright © 2025 Suzhou Pharma Machinery Co., Ltd. | Privacy Policy  Sitemap
Contact us
email
whatsapp
contact customer service
Contact us
email
whatsapp
cancel
Customer service
detect